ODE=ODE_0_Open_Drain_Disabled, HYS=HYS_0_Hysteresis_Disabled, PUS=PUS_0_100K_Ohm_Pull_Down, SRE=SRE_0_Slow_Slew_Rate, PUE=PUE_0_Keeper, PKE=PKE_0_Pull_Keeper_Disabled, SPEED=SPEED_0_Low, DSE=DSE_0_output_driver_disabled_
SW_PAD_CTL_PAD_GPIO_SD_B1_10 SW PAD Control Register
SRE | Slew Rate Field 0 (SRE_0_Slow_Slew_Rate): Slow Slew Rate 1 (SRE_1_Fast_Slew_Rate): Fast Slew Rate |
DSE | Drive Strength Field 0 (DSE_0_output_driver_disabled_): output driver disabled; 1 (DSE_1_R0_150_Ohm___3_3V__260_Ohm_1_8V): R0(150 Ohm @ 3.3V, 260 Ohm@1.8V) 2 (DSE_2_R0_2): R0/2 3 (DSE_3_R0_3): R0/3 4 (DSE_4_R0_4): R0/4 5 (DSE_5_R0_5): R0/5 6 (DSE_6_R0_6): R0/6 7 (DSE_7_R0_7): R0/7 |
SPEED | Speed Field 0 (SPEED_0_Low): 50MHz 1 (SPEED_1_Medium): 100MHz - 150MHz 2 (SPEED_2_Medium): 100MHz - 150MHz 3 (SPEED_3_Maximum): 150MHz - 200MHz |
ODE | Open Drain Enable Field 0 (ODE_0_Open_Drain_Disabled): Open Drain Disabled 1 (ODE_1_Open_Drain_Enabled): Open Drain Enabled |
PKE | Pull / Keep Enable Field 0 (PKE_0_Pull_Keeper_Disabled): Pull/Keeper Disabled 1 (PKE_1_Pull_Keeper_Enabled): Pull/Keeper Enabled |
PUE | Pull / Keep Select Field 0 (PUE_0_Keeper): Keeper 1 (PUE_1_Pull): Pull |
PUS | Pull Up / Down Config. Field 0 (PUS_0_100K_Ohm_Pull_Down): 100K Ohm Pull Down 1 (PUS_1_47K_Ohm_Pull_Up): 47K Ohm Pull Up 2 (PUS_2_100K_Ohm_Pull_Up): 100K Ohm Pull Up 3 (PUS_3_22K_Ohm_Pull_Up): 22K Ohm Pull Up |
HYS | Hyst. Enable Field 0 (HYS_0_Hysteresis_Disabled): Hysteresis Disabled 1 (HYS_1_Hysteresis_Enabled): Hysteresis Enabled |